CB Accu-Trim

The CB Accu-Trim is a stand alone, O2 trim control package ideal for those systems without other high-end control requirements. The CB Accu-Trim O2 Trim System is a PLC-based control system designed to maintain the proper fuel-to-air ratio of a boiler/burner. The system will automatically compensate for changes in temperature, barometric pressure, or fuel characteristics, [ . . . ]  Full Description »





CB Accu-Draft

The Cleaver-Brooks Accu-Draft is a stand-alone, stack draft control system designed to maintain stack draft on set point throughout the firing range of the boiler. The Cleaver-Brooks Accu-Draft is a stand-alone, stack draft control system designed to maintain stack draft on set point throughout the firing range of the boiler. This is achieved by modulating [ . . . ]  Full Description »





Levelmaster

The C-B LevelMaster is a state-of-the-art water level control system that monitors and displays boiler water level. The magnostrictive design allows for precise measurement of water level. Advanced technology alerts the operator if the level float is slowing down in relation to normal movement and prompts the operator to perform a water column blowdown. The [ . . . ]  Full Description »





PCS140e.1

The PCS140e.1 is a simple pump control system with lead/lag sequencing on a timed rotation, “first on first off” basis, or manual rotation (user-selectable). Pumps are turned on or off as required to maintain a pressure set point within a user-configurable deadband. The PCS140e.1 can control from 2 to 4 pumps for on-off control (no [ . . . ]  Full Description »





LCS250e.1

The LCS250e.1 is a level-control system which uses 1 or 2 modulating valves to maintain water level in a two-tank system. Level control is provided for the DA tank while the surge tank receives feed control, with a bias to limit the valve position according to surge tank level. The system accepts a 4-20 ma [ . . . ]  Full Description »





LCS150e.1

The LCS150e.1 is a level-control system which uses 1 or 2 modulating valves to maintain water level in a single tank. The system accepts a 4-20 ma input for use as a level signal. Alarms denote High-High-, Low-, Low-Low-, and Low-water cut-off levels. Data is available via Modbus RTU communications or logged to an optional [ . . . ]  Full Description »





ADAC

The ADAC is a PLC-based deaerator/surge tank control system designed to monitor all points on a deaerator or surge tank and control the pumps in either on/off or variable speed drives. The ADAC can control multiple input valves, condensate return, freshwater makeup, emergency makeup, and more. Data is made available to communicate with most BAS [ . . . ]  Full Description »





NATCOM Custom Control Systems

NATCOM manufactures control systems for any combustion application. Regardless of the level of complexity of your system, we will provide state-of-the-art hardware and programming for safe, reliable, and efficient operation with a user-friendly interface. NATCOM provides custom-engineered BMS and combustion control systems to meet each project’s specifications. Our systems are for highly specialized applications requiring [ . . . ]  Full Description »





Universal Data Logger

The Universal Monitoring System allows you to connect up to 4 analog instruments or signals per boiler to monitor and log data in CSV file format. Completely stand alone and will work with any brand of boiler. The system accepts up to 4 analog inputs per boiler from items like flow, pressure, or temperature instruments. [ . . . ]  Full Description »





Premium Web Server

The Premium Monitoring System replicates graphical and text boiler information and logs data in CSV file format. Completely stand alone and will integrate with Cleaver-Brooks Hawk boiler products. The system connects to up to 3 Hawk equipped boilers on the same Ethernet network and pulls data in from each. Replicates the boiler overview display, Burner [ . . . ]  Full Description »